Lock each destination generator SKU with a controlled record of output architecture, receptacles, protection, mating accessories, evidence, and revisions.
“Outlet × 2” is not enough to approve a generator stock-keeping unit (SKU). Record each outlet's exact identity, output circuit, protection and supplied plug or cord in one destination-specific matrix. Return the record if the quote, sample and production files describe different sets.
This guide covers generator-side outputs and supplied accessories. It does not approve building inlets, field wiring, transfer equipment, backfeeding or installation.
Freeze one SKU identity before discussing outlets
Begin with one SKU and revision. The same generator platform may have different panels, labels, accessories and electrical builds. A connector photo or family name cannot define the order.
Link that SKU to the supplier's quote number, model/build and response revision. Record the destination, sales channel or intended use, and document language. If a physical sample exists, give it a unique ID.
The controlled identity should appear on or link to:
- the quotation and approved configuration schedule.
- the electrical basis and applicable output drawing.
- the panel drawing and interface list.
- sample photographs and deviation record.
- nameplate, panel labels, manual, carton, and packing artwork.
- the approved bill of materials and production change record.
“Same as the sample” is incomplete when the sample has no ID or the accepted differences are not recorded. “Standard configuration” is also incomplete unless the supplier names the exact controlled revision that the phrase represents.
The generator documents before order checklist covers the wider document pack. This guide controls the output-interface subset inside it.
Separate output architecture from connector choice
Define the electrical output before choosing the connector. The supplier must state what feeds each receptacle on the exact offered build; the connector's face does not reveal the whole circuit.
Start with fields, not assumed values:
- rated and maximum output values, including the terminology and controlling document used for each.
- voltage, frequency, phase, and any selectable or separately available output states.
- AC, DC, or other stated output categories that appear on the panel.
- the source path or circuit associated with each interface ID.
- output capacity shared among interfaces and restrictions on simultaneous use, where applicable.
- the protection device or protection path associated with each interface.
- the exact document, drawing, page, and revision supporting the return.
Use the generator voltage and frequency checklist to establish the destination electrical basis. That basis does not, by itself, select a connector. Two interfaces can look alike while their functions, ratings, conductor arrangements, controlling documents, or permitted applications differ.
Neutral, protective-conductor, bonding, and earthing questions also stay tied to the offered build and its intended use. Record the supplier’s model-specific document reference and assign any unresolved system question to the qualified project authority. Do not infer an arrangement from a photograph or transfer a conclusion from another generator.
Build the Destination SKU Interface Matrix
Create one row for every physical generator output interface. A row represents a controlled object, not a marketing label such as “EU socket,” “US outlet,” “industrial socket,” or “universal socket.”
| Record block | Buyer sends | Supplier returns |
|---|---|---|
| SKU control | Buyer SKU, revision, destination, application boundary, and language | Quotation/build identity, response revision, date, and owner |
| Electrical basis | Required voltage, frequency, phase, and rating terminology from the project record | Offered values, rated/maximum basis, output architecture, and source document |
| Interface identity | Required purpose, interface ID, quantity, and location need | Exact designation, manufacturer/part number where controlled, count, panel location, and drawing/photo reference |
| Physical definition | Required mating relationship and any project constraint | Pole/wire/conductor-function record, grounding-contact geometry, locking form, mounting form, and orientation as documented |
| Rating source | Requested rating fields | Marked ratings, units, controlling standard or component document, revision, and label photograph |
| Circuit and protection | Required protection/evidence fields | Circuit ID, protection type/identity, associated interfaces, shared relationship, limitations, and drawing reference |
| Cover and environment | Requested cover or environmental condition | Included cover and stated environmental claim, plus the document, scope, and condition controlling it |
| Label and artwork | Required language, units, warnings, and buyer artwork IDs | Panel mark, nameplate, warning, manual, carton, and packing artwork revisions |
| Mating supply | Required plug, cord set, or loose accessory and quantity | Exact accessory identity, inclusion/exclusion, rating source, per-unit quantity, packaging, and BOM/packing-list reference |
| Evidence | Required document and conformity-evidence categories | File title/number/revision, issuer, object and build covered, status, limitation, and open gap |
| Approval and change | Sample reference, approval owner, deviation rule, and change rule | Sample status, deviations, production status, and applicable change notice and revision |
Blank cells are unresolved. They do not mean “use the supplier default.” Keep the words used in the controlling document; do not replace an exact designation with a friendlier but broader regional name.
Link each row to its source document and revision. A connector rating, weather-protection claim or conformity statement must name the object it covers. Without that scope, the buyer cannot judge whether it applies to the quote.
When an OEM order changes the panel, receptacles, protection labels, cord sets, manual, or packing list, attach the destination interface matrix to the BEAR OEM and private-label project review.
Match the load path without assuming an adapter solves it
Trace the whole path from the generator output through the receptacle, plug and cord to the intended load. Each connection needs a documented basis. Matching a visible shape or a voltage label is only one part of that review.
For each intended load path, put these identities side by side:
| Path object | Minimum identity to record |
|---|---|
| Generator output | Exact offered build, output state, circuit/interface ID, and controlling drawing |
| Generator receptacle | Full designation, documented conductor functions/geometry, ratings, and protection association |
| Mating plug | Exact designation, part identity where controlled, markings, and compatibility source |
| Cord set | Both end configurations, cable/assembly identity, ratings, length if specified, and document source |
| Connected equipment | Exact input-interface requirement from the equipment maker or project record |
An adapter adds a connection at each end; it does not resolve missing electrical data. Voltage, frequency, phase, conductor functions, ratings and protection still need review. If an adapter or conversion lead is proposed, give it a separate accessory row with both end identities and the applicable documents.
This comparison is for product and RFQ documentation. It is not permission to connect a generator to building wiring. Building inlets, transfer equipment, fixed wiring, field installation, protection design, grounding or earthing design, and commissioning remain outside this page.
Lock protection, evidence, and labels to each interface
An outlet count without its circuit map can hide important differences between quotations. Require every interface row to point to its associated protection and show whether several receptacles share a circuit, device, or output limit.
The supplier return should state:
- interface ID and circuit ID.
- protection-device type and exact identity where controlled.
- ratings and markings as stated in the applicable document.
- which interfaces share the device or output path.
- limits or simultaneous-use conditions stated for the offered build.
- drawing, data sheet, label, and manual references with revisions.
Keep component evidence separate from generator evidence and destination acceptance. A receptacle's document cannot by itself establish conformity or market eligibility for the complete SKU.
For each report, certificate or declaration, record its identity, issuer and status. Add the covered object, model/build, destination scope, revision and exclusions. Return evidence that cannot be tied to the offered set.
Visible information must agree with that record. Compare the panel marking, receptacle marking, protection label, nameplate, warnings, manual illustrations, and packaging copy. Return the pack when a label rounds, renames, or contradicts a controlled value or interface designation.
Approve plugs, cords, and loose accessories separately
“Plug included” does not identify the shipment contents. Give each mating plug, finished cord set or loose adapter its own row. The buyer needs to know exactly which object ships and which documents cover it.
| Accessory field | Supplier return required |
|---|---|
| Supply type | Mating plug, finished cord set, extension assembly, adapter, or another precisely named item |
| Exact identity | Designation, manufacturer/part number where controlled, end A, end B, and relevant markings |
| Quantity | Per generator, per carton, spare quantity, or explicitly excluded |
| Assembly scope | Factory-assembled product or loose parts; do not imply field assembly instructions |
| Rating source | Values, units, controlling document, revision, and scope |
| Packaging | Bag/box/kit identity, label, barcode or internal SKU where applicable, and packing-list line |
| Evidence | Data sheet, drawing, photo set, declaration/certificate/report category requested, and applicability |
The quotation, packing list, accessory artwork, manual, sample package, and BOM should all use the same identity and quantity. If a connector is required but not supplied, the commercial record should say so directly instead of leaving the buyer to infer an exclusion.
Reconcile sample, artwork, and production records
Sample approval is a revision decision, not a visual impression. Before release, compare the accepted interface matrix against the physical sample and every file that will guide production or reach the customer.
Use a cross-check register:
| Record | What must agree |
|---|---|
| Quotation/configuration schedule | SKU, electrical basis, interface set, accessories, evidence scope, and exclusions |
| Panel drawing | Interface IDs, designations, count, position, protection mapping, and labels |
| Sample photo pack | Sample ID, clear face/marking views, panel layout, covers, protection labels, and supplied accessories |
| Manual and artwork | Interface names, ratings as approved, warnings, illustrations, language, and revision |
| Packing list and carton | Included plugs/cords/adapters, quantities, internal identities, and label revision |
| Production BOM | Receptacle, protection, cover, harness/assembly, label, and accessory line identities |
Record every deviation as accepted, rejected, or still open. Silence is not acceptance.
Reopen the affected rows if a connector, output panel, protection device, cord or accessory changes. Changes to labels, manuals, artwork or the electrical build need the same check. Record part substitutions before approving the new production revision.
Apply COMPARE, RETURN, or STOP
The interface matrix controls three decisions. It does not manufacture a compatibility or compliance promise.
COMPAREmeans quotations describe their interface scope on the same controlled basis. The SKU, output architecture, interface identities, protection mapping, accessories, source files, revisions, and open items can be compared row by row.RETURNmeans a supplier-controlled answer or file is missing, broad, stale, or inconsistent. Return the named row and request the exact designation, scope, evidence, drawing, photo, label, accessory, or revision required.STOPmeans the records conflict, the output architecture is unresolved, or approval depends on a destination compliance, building connection, protection, grounding/earthing, safety, or installation decision with no qualified owner.
Return or stop when any of these remains:
- the quotation uses only a regional or generic outlet name.
- the interface shape is being used as proof of ratings or conductor functions.
- output values or rating terminology differ among the quotation, nameplate proposal, data sheet, and manual.
- a connector, circuit, protection device, or shared-output relationship has no traceable document.
- the sample, panel drawing, artwork, packing list, and BOM show different interfaces or quantities.
- a supplied plug, cord, or adapter lacks an exact identity, quantity, scope, or rating source.
- a component document is being used as whole-generator or destination approval.
- an unapproved substitution appears after sample acceptance.
- closing the row would require field-wiring or system-design assumptions.
COMPARE is permission to compare commercial offers. It is not final engineering approval of the generator, connected load, installation, or destination conformity.
Send one controlled interface RFQ
Send the current Destination SKU Interface Matrix with the quote request. Identify the buyer SKU and revision, destination, intended use, language and quantity. Attach the electrical-basis record and the intended load's connector documents. List the requested evidence, sample plan and open decisions with their owners.
Require the supplier to return:
- quotation/build identity and response revision.
- rated/maximum basis, voltage, frequency, phase, output architecture, and controlling documents.
- one complete row for each generator output interface.
- circuit/protection mapping and any documented shared-output limitations.
- exact mating plug, cord set, and loose-accessory identities, quantities, inclusions, and packing references.
- panel drawing, sample photo plan, labels, manual/artwork, evidence register, and revisions.
- deviations, exclusions, unanswered fields, and the owner of each next decision.
- sample-approval and production-release state plus the rule for future changes.
For a BEAR quotation review, send Miya the completed interface matrix. Include the destination, electrical-basis record, intended load-interface documents, accessories, evidence request, quantity and open items. BEAR must identify the exact offered build and return records for that scope. Building connection, installation, commissioning and final project approval remain with qualified project parties.